X-ray machine THR-XR-7000 is wildly used in Department of Orthopedics, Department of General Surgery, Orthopedics, Urology Surgery, Spine Surgery, Abdominal Surgery, Department of Pain Treatment, Cardiology, Gastroenterology, Gynecology, Operating Room, etc.
Item | Quantity |
Console | 1 |
High voltage generator | 1 |
X ray tube | 1 |
Collimator | 1 |
Diagnostic table | 1 |
Grid | 2 |
Dynamic flat panel detector | 1 |
Image acquisition workstation | 1 |
Image processing software(Optional) | 1 |
Accessory | 1 |
Item | Content | Technical parameter |
Power Supply | Voltage | 380V±38V |
frequency | 50Hz±1Hz | |
capacity | ≥105kVA | |
internal resistance | ≤0.17Ω | |
High voltage generator | Maximum output power | 65.5kW |
Main inverter frequency | 500khz, tolerance ± 20% | |
Radiography tube voltage | 40kV~150kV | |
Radiography tube current | 10mA~800mA regulation in steps | |
Radiography time | 1ms~ 10000ms regulation in steps | |
Radiography mAs | 0.1~1000 mAs | |
Fluoroscopy voltage | 40kV~ 125kV Continuously adjustable | |
Fluoroscopy current | 0.5mA~ 10mA (Continuously fluoroscopy) 5mA~ 20mA (pulse fluoroscopy) | |
Collimator | Equivalent total filtration | ≥1mmAL |
X ray tube | Nominal anode input power | Big focus 75kW small focus 27kW |
Anode heat capacity | 210KJ(300kHU) | |
Component heat capacity | 900kJ(1250kHU) | |
Rotating anode speed | 9700rpm(180 Hz) | |
Tube focus | Big focus 1.2mm / Big focus 0.6mm | |
Target angle | 12° | |
Diagnostic | Table rotating range | +90 ° ~ 0 ° ~ -25 ° |
Longitudinal movement of point device | 1000mm±20mm | |
Lifting range of bed surface | Not less than 300mm; tolerance ±10mm | |
The load-bearing capacity of the bed: | 200kg | |
SID | 1000mm~1800mm;Tolerance ± 20 mm | |
Rotating foot pedal(optional) | 360°Infinite rotation. | |
Filter grid | 498.5x449mm 230L/INCH 10:1,focal length:100cm 498.5x449mm 103L/INCH 10:1,focal length:180cm | |
Dynamic flat panel detector | Effective area | 434mm(H)×434mm(V) |
Prime matrix | 3072(H)×3072(V) | |
Prime particle spacing | 139μm | |
Pulse fluoroscopy | 12fps / 1408 x 1408 16fps / 1024 x 1024 22fps / 768x768 | |
Continuous fluoroscopy | 13fps / 1408 x 1408 20fps / 1024 x 1024 30fps / 768x768 | |
Sequence radiography | 3fps/3072 x 3072 6fps/1536 x 1536 | |
Point piece | 3072 x 3072 1536 x 1536 | |
Spatial resolution | ≥3.7lp/mm | |
A / D Transformation | 16bit | |
Energy range | 40 ~ 150 kVp | |
Image output and control | Gigabit lan | |
Image processing software(Optional) | Image sending function | Send the image to other DICOM receiver devices |
Image processing software(Optional) | Burn disc function | Export selected exams to CD/DCD discs, with CD player software |