PRODUCT DETAILS
PPRODUCT DETAILS
THR-ECG-120G

THR-ECG-120G

0.00
0.00
  

THR-ECG-120G

Digital 12 Channel ECG Machine

Feature of ecg-1200g digital 12 channel ecg:

1. 8"TFT Color LCD shows the working status and ECG waveform. Check the waveform before printing to save record paper.

2. 12 Leads ECG simultaneous gather, digital signal processing, to get the ECG waveforms of higher quality through the AC, DFT and EMG filtering of the ECG signals.

3. Simultaneous display of 3/6/12 leads ECG waveform, and the state of printing mode, sensitivity, speed, filter etc, to be easy for contrast diagnosis.

4. Multiply printing modes and formats, including 12*1, 6*2+1(rhythm lead), 6*2, rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual and freeze, etc. The length of printed wave can be adjusted and simultaneity the function of periodic printing is offered to satisfy different applications.

5. The instrument has the functions of auto-analysis and auto-diagnosis of regular ECG waveform parameters, provides measurement parameters such as HR, P-R interval, P Duration, QRS Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc and auto-diagnosis conclusion to reduce doctor's burden.  

6. AC/DC power supply. Built-in rechargeable lithium polymer battery. At the best DC state, it can standby for 4 hours, print continually for 90 min, and print 150 pieces of ECG waveform to satisfy the need of visiting patients and physical examination.

7. Built-in MSF, can store more than 1000 cases, convenient for doctor's case review and information statistics.

8. System provides Chinese/English/Spanish/Turkish operation interface and can print multiply languages report. 

9. System provides multiply printing speeds, including 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s, and abstract conclusion graph printing.    

 

Main performance of ecg-1200g digital 12 channel ecg:

Input way

Floating and defibrillation protection

Lead

Standard 12 leads(model:BIP0057)

Patient leak current

<10µA

Input impedance

≥50MΩ

Frequency response

0.05Hz~150Hz(-3dB)

Time constant

Time constant>3.2s

CMRR

 >60dB, >100dB( Adding filter)

EMG interference filter

35Hz(-3dB)

Sensitivity selections

2.5,5,10,20,40mm/mV, error:±5%.

Standard sensitivity is 10mm/mV±0.2mm/mV.

Auto record

Record setup according to auto record format and mode, automatically changing leads, measuring and analysing

Rhythm record

Record setup according to rhythm record format and mode, automatically measuring and analysing.

Manual record

Record setup according to manual record format, manually changing leads

Measurement parameters

HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P A*is, QRS A*is, T A*is, R(V5) , S(V1) , R(V5)+S(V1)

Product safety type

Class I CF applied part; there is defibrillation and pacing protection circuit in it

Enduring polarization voltage

±300mV

Noise level

≤15µVp-p

Fuse specification

2 pcs φ5*20mm AC time lag; T1.6A/250V(Power supply 220V)

 

 Printing:

Recording way

Thermal printing system

Specification of recording paper

210mm(W)*20m(L) high-speed thermal paper

Paper speed

Auto record: 25mm/s, 50mm/s, error:±5%
Rhythm record: 25mm/s, 50mm/s, error:±5%
Manual record:5mm/s, 6.25mm/s, 10mm/s,     
                  

                        12.5mm/s,25mm/s,50mm/s,error:±5%                        

  

Environment conditions:

Environment temperature

+5°C~+35°C

Relative humidity

≤80%

Power supply

AC:100V~240V,50/60Hz
DC:14.8V, 3700 mAh rechargeable lithium battery

Atmospheric pressure

86kPa~106kPa